mirror of
https://git.freebsd.org/src.git
synced 2026-01-11 19:57:22 +00:00
gvinum(8): Remove userland tool for managing vinum volumes
Reviewed by: imp, emaste Differential Revision: https://reviews.freebsd.org/D48542
This commit is contained in:
parent
f87bb59676
commit
e51036fbf3
9 changed files with 4 additions and 1987 deletions
|
|
@ -51,6 +51,10 @@
|
|||
# xargs -n1 | sort | uniq -d;
|
||||
# done
|
||||
|
||||
# 20250123: Remove gvinum(8)
|
||||
OLD_FILES+=sbin/gvinum
|
||||
OLD_FILES+=usr/share/man/man8/gvinum.8.gz
|
||||
|
||||
# 20250122: Remove publickey(5) stuff
|
||||
OLD_FILES+=usr/bin/chkey
|
||||
OLD_FILES+=usr/bin/keylogin
|
||||
|
|
|
|||
|
|
@ -24,7 +24,6 @@ SUBDIR=adjkerntz \
|
|||
geom \
|
||||
ggate \
|
||||
growfs \
|
||||
gvinum \
|
||||
ifconfig \
|
||||
init \
|
||||
kldconfig \
|
||||
|
|
|
|||
|
|
@ -168,8 +168,6 @@ STRIPE
|
|||
.It
|
||||
UNION
|
||||
.It
|
||||
VINUM (deprecated)
|
||||
.It
|
||||
VIRSTOR
|
||||
.El
|
||||
.Sh ENVIRONMENT
|
||||
|
|
@ -221,7 +219,6 @@ geom md unload
|
|||
.Xr gshsec 8 ,
|
||||
.Xr gstripe 8 ,
|
||||
.Xr gunion 8 ,
|
||||
.Xr gvinum 8 ,
|
||||
.Xr gvirstor 8
|
||||
.Sh HISTORY
|
||||
The
|
||||
|
|
|
|||
|
|
@ -1,13 +0,0 @@
|
|||
PACKAGE=geom
|
||||
PROG= gvinum
|
||||
SRCS= gvinum.c gvinum.h geom_vinum_share.c
|
||||
MAN= gvinum.8
|
||||
|
||||
WARNS?= 2
|
||||
CFLAGS+= -I${SRCTOP}/sys -I${SYSROOT:U${DESTDIR}}/${INCLUDEDIR}/edit
|
||||
|
||||
LIBADD= edit geom
|
||||
|
||||
.PATH: ${SRCTOP}/sys/geom/vinum
|
||||
|
||||
.include <bsd.prog.mk>
|
||||
|
|
@ -1,18 +0,0 @@
|
|||
# Autogenerated - do NOT edit!
|
||||
|
||||
DIRDEPS = \
|
||||
include \
|
||||
include/xlocale \
|
||||
lib/${CSU_DIR} \
|
||||
lib/libc \
|
||||
lib/libcompiler_rt \
|
||||
lib/libedit \
|
||||
lib/libedit/readline \
|
||||
lib/libgeom \
|
||||
|
||||
|
||||
.include <dirdeps.mk>
|
||||
|
||||
.if ${DEP_RELDIR} == ${_DEP_RELDIR}
|
||||
# local dependencies - needed for -jN in clean tree
|
||||
.endif
|
||||
|
|
@ -1,460 +0,0 @@
|
|||
.\" Copyright (c) 2005 Chris Jones
|
||||
.\" All rights reserved.
|
||||
.\"
|
||||
.\" This software was developed for the FreeBSD Project by Chris Jones
|
||||
.\" thanks to the support of Google's Summer of Code program and
|
||||
.\" mentoring by Lukas Ertl.
|
||||
.\"
|
||||
.\" Redistribution and use in source and binary forms, with or without
|
||||
.\" modification, are permitted provided that the following conditions
|
||||
.\" are met:
|
||||
.\" 1. Redistributions of source code must retain the above copyright
|
||||
.\" notice, this list of conditions and the following disclaimer.
|
||||
.\" 2. Redistributions in binary form must reproduce the above copyright
|
||||
.\" notice, this list of conditions and the following disclaimer in the
|
||||
.\" documentation and/or other materials provided with the distribution.
|
||||
.\"
|
||||
.\" THIS SOFTWARE IS PROVIDED BY AUTHOR AND CONTRIBUTORS ``AS IS'' AND
|
||||
.\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
|
||||
.\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
|
||||
.\" ARE DISCLAIMED. IN NO EVENT SHALL AUTHOR OR CONTRIBUTORS BE LIABLE
|
||||
.\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL
|
||||
.\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS
|
||||
.\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION)
|
||||
.\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
|
||||
.\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY
|
||||
.\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
||||
.\" SUCH DAMAGE.
|
||||
.\"
|
||||
.Dd January 23, 2025
|
||||
.Dt GVINUM 8
|
||||
.Os
|
||||
.Sh NAME
|
||||
.Nm gvinum
|
||||
.Nd Logical Volume Manager control program
|
||||
.Sh DEPRECATION NOTICE
|
||||
.Nm
|
||||
and associated
|
||||
.Xr geom 4
|
||||
kernel support is deprecated, and is not be available in
|
||||
.Fx 15.0
|
||||
and later.
|
||||
Users are advised to migrate to
|
||||
.Xr gconcat 8 ,
|
||||
.Xr gmirror 8 ,
|
||||
.Xr gstripe 8 ,
|
||||
.Xr graid 8 ,
|
||||
or
|
||||
.Xr zfs 8 .
|
||||
More information is available at
|
||||
.Pa https://wiki.freebsd.org/DeprecationPlan/gvinum .
|
||||
.Sh SYNOPSIS
|
||||
.Nm
|
||||
.Op Ar command
|
||||
.Op Fl options
|
||||
.Sh COMMANDS
|
||||
.Bl -tag -width indent
|
||||
.It Ic attach Ar plex volume Op Cm rename
|
||||
.It Ic attach Ar subdisk plex Oo Ar offset Oc Op Cm rename
|
||||
Attach a plex to a volume, or a subdisk to a plex.
|
||||
If offset is specified, the subdisk will be attached to the given offset within
|
||||
the plex.
|
||||
If rename is specified, the subdisk or plex will change name according to the
|
||||
object it attaches to.
|
||||
.It Ic checkparity Oo Fl f Oc Ar plex
|
||||
Check the parity blocks of a RAID-5 plex.
|
||||
The parity check will start at the
|
||||
beginning of the plex if the
|
||||
.Fl f
|
||||
flag is specified, or otherwise at the location of the parity check pointer,
|
||||
the first location at which plex's parity is incorrect.
|
||||
All subdisks in the
|
||||
plex must be up for a parity check.
|
||||
.It Ic concat Oo Fl fv Oc Oo Fl n Ar name Oc Ar drives
|
||||
Create a concatenated volume from the specified drives.
|
||||
If no name is specified, a unique name will be set by
|
||||
.Ic gvinum .
|
||||
.It Ic create Oo Fl f Oc Op Ar description-file
|
||||
Create a volume as described in
|
||||
.Ar description-file .
|
||||
If no
|
||||
.Ar description-file
|
||||
provided, opens an editor and provides the current
|
||||
.Nm
|
||||
configuration for editing.
|
||||
The
|
||||
.Fl f
|
||||
flag will make gvinum ignore any errors regarding creating objects that already
|
||||
exists.
|
||||
However, in contrast to vinum, objects that are not properly named in the
|
||||
.Ar description-file
|
||||
will not be created when the
|
||||
.Fl f
|
||||
flag is given.
|
||||
.It Ic detach Oo Fl f Oc Op Ar plex | subdisk
|
||||
Detach a plex or subdisk from the volume or plex to which it is
|
||||
attached.
|
||||
.It Ic grow Ar plex device
|
||||
Grow a plex by creating a gvinum drive and subdisk on device and attach it to
|
||||
the plex.
|
||||
If required by the plex organization, it will be put into the growable state.
|
||||
.It Ic help
|
||||
Provides a synopsis of
|
||||
.Nm
|
||||
commands and arguments.
|
||||
.It Ic l | list Oo Fl rvV Oc Op Ar volume | plex | subdisk
|
||||
.It Ic ld Oo Fl rvV Oc Op Ar drive ...
|
||||
.It Ic ls Oo Fl rvV Oc Op Ar subdisk ...
|
||||
.It Ic lp Oo Fl rvV Oc Op Ar plex ...
|
||||
.It Ic lv Oo Fl rvV Oc Op Ar volume ...
|
||||
List information about the relevant object(s).
|
||||
The
|
||||
.Fl r
|
||||
flag provides recursive display, showing each object's subordinate objects in
|
||||
proper relation.
|
||||
The
|
||||
.Fl v
|
||||
and
|
||||
.Fl V
|
||||
flags provide progressively more detailed output.
|
||||
.It Ic mirror Oo Fl fsv Oc Oo Fl n Ar name Oc Ar drives
|
||||
Create a mirrored volume from the specified drives.
|
||||
It requires at least a multiple of 2 drives.
|
||||
If no name is specified, a unique name will be set by gvinum.
|
||||
If the
|
||||
.Fl s
|
||||
flag is specified, a striped mirror will be created, and thus requires a
|
||||
multiple of 4 drives.
|
||||
.It Ic move | mv Fl f Ar drive subdisk Op Ar ...
|
||||
Move the subdisk(s) to the specified drive.
|
||||
The
|
||||
.Fl f
|
||||
flag is required, as all data on the indicated subdisk(s) will be destroyed as
|
||||
part of the move.
|
||||
This can currently only be done when the subdisk is
|
||||
not being accessed.
|
||||
.Pp
|
||||
If a single subdisk is moved, and it forms a part of a RAID-5 plex, the moved
|
||||
subdisks will need to be set to the
|
||||
.Dq stale
|
||||
state, and the plex will require a
|
||||
.Ic start
|
||||
command.
|
||||
If multiple subdisk(s) is moved, and form part of a RAID-5 plex, the
|
||||
moved disk(s) will need to be set to the
|
||||
.Dq up
|
||||
state and the plex will require a
|
||||
.Ic rebuildparity
|
||||
command.
|
||||
If the subdisk(s) form part of a plex that is mirrored with other
|
||||
plexes, the plex will require restarting and will sync once restarted.
|
||||
Moving
|
||||
more than one subdisk in a RAID-5 plex or subdisks from both sides of a
|
||||
mirrored plex volume will destroy data.
|
||||
Note that parity rebuilds and syncing
|
||||
must be started manually after a move.
|
||||
.It Ic printconfig
|
||||
Write a copy of the current configuration to standard output.
|
||||
.It Ic quit
|
||||
Exit
|
||||
.Nm
|
||||
when running in interactive mode.
|
||||
Normally this would be done by entering the
|
||||
EOF character.
|
||||
.It Ic raid5 Oo Fl fv Oc Oo Fl s Ar stripesize Oc Oo Fl n Ar name Oc Ar drives
|
||||
Create a RAID-5 volume from the specified drives.
|
||||
If no name is specified, a unique name will be set by
|
||||
.Ic gvinum .
|
||||
This organization requires at least three drives.
|
||||
.It Ic rename Oo Fl r Oc Ar drive | subdisk | plex | volume newname
|
||||
Change the name of the specified object.
|
||||
The
|
||||
.Fl r
|
||||
flag will recursively rename subordinate objects.
|
||||
.Pp
|
||||
Note that device nodes will not be renamed until
|
||||
.Nm
|
||||
is restarted.
|
||||
.It Ic rebuildparity Oo Fl f Oc Ar plex
|
||||
Rebuild the parity blocks of a RAID-5 plex.
|
||||
The parity rebuild will start at
|
||||
the beginning of the plex if the
|
||||
.Fl f
|
||||
flag is specified, or otherwise at the location of the parity check pointer.
|
||||
All subdisks in the plex must be up for a parity check.
|
||||
.It Ic resetconfig Oo Fl f Oc
|
||||
Reset the complete
|
||||
.Nm
|
||||
configuration.
|
||||
.It Ic rm Oo Fl r Oc Ar volume | plex | subdisk
|
||||
Remove an object and, if
|
||||
.Fl r
|
||||
is specified, its subordinate objects.
|
||||
.It Ic saveconfig
|
||||
Save
|
||||
.Nm
|
||||
configuration to disk after configuration failures.
|
||||
.It Ic setstate Oo Fl f Oc Ar state volume | plex | subdisk | drive
|
||||
Set state without influencing other objects, for diagnostic purposes
|
||||
only.
|
||||
The
|
||||
.Fl f
|
||||
flag forces state changes regardless of whether they are legal.
|
||||
.It Ic start
|
||||
Read configuration from all vinum drives.
|
||||
.It Ic start Oo Fl S Ar size Oc Ar volume | plex | subdisk
|
||||
Allow the system to access the objects.
|
||||
If necessary, plexes will be synced and rebuilt.
|
||||
If a subdisk was added to a running RAID-5 or striped plex, gvinum will
|
||||
expand into this subdisk and grow the whole RAID-5 array.
|
||||
This can be done without unmounting your filesystem.
|
||||
The
|
||||
.Fl S
|
||||
flag is currently ignored.
|
||||
.It Ic stop Oo Fl f Oc Op Ar volume | plex | subdisk
|
||||
Terminate access to the objects, or stop
|
||||
.Nm
|
||||
if no parameters are specified.
|
||||
.It Ic stripe Oo Fl fv Oc Oo Fl n Ar name Oc Ar drives
|
||||
Create a striped volume from the specified drives.
|
||||
If no name is specified, a unique name will be set by
|
||||
.Ic gvinum .
|
||||
This organization requires at least two drives.
|
||||
.El
|
||||
.Sh DESCRIPTION
|
||||
The
|
||||
.Nm
|
||||
utility communicates with the kernel component of the GVinum logical volume
|
||||
manager.
|
||||
It is designed either for interactive use, when started without
|
||||
command line arguments, or to execute a single command if the command is
|
||||
supplied on the command line.
|
||||
In interactive mode,
|
||||
.Nm
|
||||
maintains a command line history.
|
||||
.Sh OPTIONS
|
||||
The
|
||||
.Nm
|
||||
commands may be followed by an option.
|
||||
.Bl -tag -width indent
|
||||
.It Fl f
|
||||
The
|
||||
.Fl f
|
||||
.Pq Dq force
|
||||
option overrides safety checks.
|
||||
It should be used with extreme caution.
|
||||
This
|
||||
option is required in order to use the
|
||||
.Ic move
|
||||
command.
|
||||
.It Fl r
|
||||
The
|
||||
.Fl r
|
||||
.Pq Dq recursive
|
||||
option applies the command recursively to subordinate objects.
|
||||
For example, in
|
||||
conjunction with the
|
||||
.Ic lv
|
||||
command, the
|
||||
.Fl r
|
||||
option will also show information about the plexes and subdisks belonging to
|
||||
the volume.
|
||||
It is also used by the
|
||||
.Ic rename
|
||||
command to indicate that subordinate objects such as subdisks should be renamed
|
||||
to match the object(s) specified and by the
|
||||
.Ic rm
|
||||
command to delete plexes belonging to a volume and so on.
|
||||
.It Fl v
|
||||
The
|
||||
.Fl v
|
||||
.Pq Dq verbose
|
||||
option provides more detailed output.
|
||||
.It Fl V
|
||||
The
|
||||
.Fl V
|
||||
.Pq Dq "very verbose"
|
||||
option provides even more detailed output than
|
||||
.Fl v .
|
||||
.El
|
||||
.Sh ENVIRONMENT
|
||||
.Bl -tag -width ".Ev EDITOR"
|
||||
.It Ev EDITOR
|
||||
The name of the editor to use for editing configuration files, by
|
||||
default
|
||||
.Xr vi 1
|
||||
is invoked.
|
||||
.El
|
||||
.Sh FILES
|
||||
.Bl -tag -width ".Pa /dev/gvinum/plex"
|
||||
.It Pa /dev/gvinum
|
||||
directory with device nodes for
|
||||
.Nm
|
||||
objects
|
||||
.El
|
||||
.Sh EXAMPLES
|
||||
To create a mirror on disks /dev/ada1 and /dev/ada2, create a filesystem,
|
||||
mount, unmount and then stop
|
||||
.Ic gvinum :
|
||||
.Pp
|
||||
.Dl "gvinum mirror /dev/ada1 /dev/ada2"
|
||||
.Dl "newfs /dev/gvinum/gvinumvolume0"
|
||||
.Dl "mount /dev/gvinum/gvinumvolume0 /mnt"
|
||||
.Dl "..."
|
||||
.Dl "unmount /mnt"
|
||||
.Dl "gvinum stop"
|
||||
.Pp
|
||||
To create a striped mirror on disks /dev/ada1 /dev/ada2 /dev/ada3 and
|
||||
/dev/ada4 named "data" and create a filesystem:
|
||||
.Pp
|
||||
.Dl "gvinum mirror -s -n data /dev/ada1 /dev/ada2 /dev/ada3 /dev/ada4"
|
||||
.Dl "newfs /dev/gvinum/data"
|
||||
.Pp
|
||||
To create a raid5 array on disks /dev/ada1 /dev/ada2 and /dev/ada3,
|
||||
with stripesize 493k you can use the raid5 command:
|
||||
.Pp
|
||||
.Dl "gvinum raid5 -s 493k /dev/ada1 /dev/ada2 /dev/ada3"
|
||||
.Pp
|
||||
Then the volume will be created automatically.
|
||||
Afterwards, you have to initialize the volume:
|
||||
.Pp
|
||||
.Dl "gvinum start myraid5vol"
|
||||
.Pp
|
||||
The initialization will start, and the states will be updated when it's
|
||||
finished.
|
||||
The list command will give you information about its progress.
|
||||
.Pp
|
||||
Imagine that one of the drives fails, and the output of 'printconfig' looks
|
||||
something like this:
|
||||
.Pp
|
||||
.Dl "drive gvinumdrive1 device /dev/ada2"
|
||||
.Dl "drive gvinumdrive2 device /dev/???"
|
||||
.Dl "drive gvinumdrive0 device /dev/ada1"
|
||||
.Dl "volume myraid5vol"
|
||||
.Dl "plex name myraid5vol.p0 org raid5 986s vol myraid5vol"
|
||||
.Dl "sd name myraid5vol.p0.s2 drive gvinumdrive2 len 32538s driveoffset 265s"
|
||||
.Dl "plex myraid5vol.p0 plexoffset 1972s"
|
||||
.Dl "sd name myraid5vol.p0.s1 drive gvinumdrive1 len 32538s driveoffset 265s"
|
||||
.Dl "plex myraid5vol.p0 plexoffset 986s"
|
||||
.Dl "sd name myraid5vol.p0.s0 drive gvinumdrive0 len 32538s driveoffset 265s"
|
||||
.Dl "plex myraid5vol.p0 plexoffset 0s"
|
||||
.Pp
|
||||
Create a new drive with this configuration:
|
||||
.Pp
|
||||
.Dl "drive gdrive4 device /dev/ada4"
|
||||
.Pp
|
||||
Then move the stale subdisk to the new drive:
|
||||
.Pp
|
||||
.Dl "gvinum move gdrive4 myraid5vol.p0.s2"
|
||||
.Pp
|
||||
Then, initiate the rebuild:
|
||||
.Pp
|
||||
.Dl "gvinum start myraid5vol.p0"
|
||||
.Pp
|
||||
The plex will go up from degraded mode after the rebuild is finished.
|
||||
The plex can still be used while the rebuild is in progress, although requests
|
||||
might be delayed.
|
||||
.Pp
|
||||
Given the configuration as in the previous example, growing a RAID-5 or STRIPED
|
||||
array is accomplished by using the grow command:
|
||||
.Pp
|
||||
.Dl "gvinum grow myraid5vol.p0 /dev/ada4"
|
||||
.Pp
|
||||
If everything went ok, the plex state should now be set to growable.
|
||||
You can then start the growing with the
|
||||
.Ic start
|
||||
command:
|
||||
.Pp
|
||||
.Dl "gvinum start myraid5vol.p0"
|
||||
.Pp
|
||||
As with rebuilding, you can watch the progress using the
|
||||
.Ic list
|
||||
command.
|
||||
.Pp
|
||||
For a more advanced usage and detailed explanation of gvinum, the
|
||||
handbook is recommended.
|
||||
.Sh SEE ALSO
|
||||
.Xr geom 4 ,
|
||||
.Xr geom 8
|
||||
.Sh HISTORY
|
||||
The
|
||||
.Nm
|
||||
utility first appeared in
|
||||
.Fx 5.3 .
|
||||
The
|
||||
.Nm vinum
|
||||
utility, on which
|
||||
.Nm
|
||||
is based, was written by
|
||||
.An "Greg Lehey" .
|
||||
.Pp
|
||||
The
|
||||
.Nm
|
||||
utility
|
||||
was written by
|
||||
.An "Lukas Ertl" .
|
||||
The
|
||||
.Ic move
|
||||
and
|
||||
.Ic rename
|
||||
commands and
|
||||
documentation were added by
|
||||
.An "Chris Jones"
|
||||
through the 2005 Google Summer
|
||||
of Code program.
|
||||
A partial rewrite of gvinum was done by
|
||||
.An "Lukas Ertl"
|
||||
and
|
||||
.An "Ulf Lilleengen"
|
||||
through the 2007 Google Summer of Code program.
|
||||
The documentation have been updated to reflect the new functionality.
|
||||
.Sh AUTHORS
|
||||
.An Lukas Ertl Aq Mt le@FreeBSD.org
|
||||
.An Chris Jones Aq Mt soc-cjones@FreeBSD.org
|
||||
.An Ulf Lilleengen Aq Mt lulf@FreeBSD.org
|
||||
.Sh BUGS
|
||||
Currently,
|
||||
.Nm
|
||||
does not rename devices in
|
||||
.Pa /dev/gvinum
|
||||
until reloaded.
|
||||
.Pp
|
||||
The
|
||||
.Fl S
|
||||
initsize flag to
|
||||
.Ic start
|
||||
is ignored.
|
||||
.Pp
|
||||
Moving subdisks that are not part of a mirrored or RAID-5 volume will
|
||||
destroy data.
|
||||
It is perhaps a bug to permit this.
|
||||
.Pp
|
||||
Plexes in which subdisks have been moved do not automatically sync or
|
||||
rebuild parity.
|
||||
This may leave data unprotected and is perhaps unwise.
|
||||
.Pp
|
||||
Currently,
|
||||
.Nm
|
||||
does not yet fully implement all of the functions found in
|
||||
.Nm vinum .
|
||||
Specifically, the following commands from
|
||||
.Nm vinum
|
||||
are not supported:
|
||||
.Bl -tag -width indent
|
||||
.It Ic debug
|
||||
Cause the volume manager to enter the kernel debugger.
|
||||
.It Ic debug Ar flags
|
||||
Set debugging flags.
|
||||
.It Ic dumpconfig Op Ar drive ...
|
||||
List the configuration information stored on the specified drives, or all
|
||||
drives in the system if no drive names are specified.
|
||||
.It Ic info Op Fl vV
|
||||
List information about volume manager state.
|
||||
.It Ic label Ar volume
|
||||
Create a volume label.
|
||||
.It Ic resetstats Oo Fl r Oc Op Ar volume | plex | subdisk
|
||||
Reset statistics counters for the specified objects, or for all objects if none
|
||||
are specified.
|
||||
.It Ic setdaemon Op Ar value
|
||||
Set daemon configuration.
|
||||
.El
|
||||
1450
sbin/gvinum/gvinum.c
1450
sbin/gvinum/gvinum.c
File diff suppressed because it is too large
Load diff
|
|
@ -1,41 +0,0 @@
|
|||
/*-
|
||||
* SPDX-License-Identifier: BSD-4-Clause
|
||||
*
|
||||
* Copyright (c) 1997, 1998
|
||||
* Nan Yang Computer Services Limited. All rights reserved.
|
||||
*
|
||||
* This software is distributed under the so-called ``Berkeley
|
||||
* License'':
|
||||
*
|
||||
* Redistribution and use in source and binary forms, with or without
|
||||
* modification, are permitted provided that the following conditions
|
||||
* are met:
|
||||
* 1. Redistributions of source code must retain the above copyright
|
||||
* notice, this list of conditions and the following disclaimer.
|
||||
* 2. Redistributions in binary form must reproduce the above copyright
|
||||
* notice, this list of conditions and the following disclaimer in the
|
||||
* documentation and/or other materials provided with the distribution.
|
||||
* 3. All advertising materials mentioning features or use of this software
|
||||
* must display the following acknowledgement:
|
||||
* This product includes software developed by Nan Yang Computer
|
||||
* Services Limited.
|
||||
* 4. Neither the name of the Company nor the names of its contributors
|
||||
* may be used to endorse or promote products derived from this software
|
||||
* without specific prior written permission.
|
||||
*
|
||||
* This software is provided ``as is'', and any express or implied
|
||||
* warranties, including, but not limited to, the implied warranties of
|
||||
* merchantability and fitness for a particular purpose are disclaimed.
|
||||
* In no event shall the company or contributors be liable for any
|
||||
* direct, indirect, incidental, special, exemplary, or consequential
|
||||
* damages (including, but not limited to, procurement of substitute
|
||||
* goods or services; loss of use, data, or profits; or business
|
||||
* interruption) however caused and on any theory of liability, whether
|
||||
* in contract, strict liability, or tort (including negligence or
|
||||
* otherwise) arising in any way out of the use of this software, even if
|
||||
* advised of the possibility of such damage.
|
||||
*/
|
||||
|
||||
|
||||
#define GVINUMMOD "g_vinum"
|
||||
#define GVINUMKLD "geom_vinum"
|
||||
|
|
@ -72,7 +72,6 @@ DIRDEPS+= \
|
|||
sbin/ggate/ggated \
|
||||
sbin/ggate/ggatel \
|
||||
sbin/growfs \
|
||||
sbin/gvinum \
|
||||
sbin/hastctl \
|
||||
sbin/hastd \
|
||||
sbin/ifconfig \
|
||||
|
|
|
|||
Loading…
Add table
Reference in a new issue