iDRAC driver
|
|
============
|
|
|
|
Overview
|
|
========
|
|
|
|
The integrated Dell Remote Access Controller (iDRAC_) is an out-of-band
|
|
management platform on Dell EMC servers, and is supported directly by
|
|
the ``idrac`` hardware type. This driver utilizes the Distributed
|
|
Management Task Force (DMTF) Redfish protocol to perform all of it's
|
|
functions. In older versions of Ironic, this driver leveraged
|
|
Web Services for Management (WSMAN) protocol.
|
|
|
|
iDRAC_ hardware is also supported by the generic ``ipmi`` and ``redfish``
|
|
hardware types, though with smaller feature sets.
|
|
|
|
Key features of the Dell iDRAC driver include:
|
|
|
|
* Out-of-band node inspection
|
|
* Boot device management and firmware management
|
|
* Power management
|
|
* RAID controller management and RAID volume configuration
|
|
* BIOS settings configuration
|
|
|
|
Ironic Features
|
|
---------------
|
|
|
|
The ``idrac`` hardware type extends the ``redfish`` hardware type
|
|
and supports the following Ironic interfaces:
|
|
|
|
* `BIOS Interface`_: BIOS management
|
|
* `Inspect Interface`_: Hardware inspection
|
|
* `Management Interface`_: Boot device and firmware management
|
|
* Power Interface: Power management
|
|
* `RAID Interface`_: RAID controller and disk management
|
|
* `Vendor Interface`_: eject virtual media (Redfish)
|
|
|
|
Prerequisites
|
|
-------------
|
|
|
|
The ``idrac`` hardware type requires the ``sushy`` library and the vendor extensions
|
|
to be installed on the ironic conductor node(s) if an Ironic node is
|
|
configured to use an ``idrac-redfish`` interface implementation, for example::
|
|
|
|
sudo pip install 'sushy>=5.6.0'
|
|
|
|
Enabling
|
|
--------
|
|
|
|
The iDRAC driver supports Redfish for the bios, inspect, management, power,
|
|
and raid interfaces.
|
|
|
|
The ``idrac-redfish`` implementation must be enabled
|
|
to use Redfish for an interface.
|
|
|
|
To enable the ``idrac`` hardware type, add the following to your
|
|
``/etc/ironic/ironic.conf``:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_hardware_types=idrac
|
|
enabled_management_interfaces=idrac-redfish
|
|
enabled_power_interfaces=redfish
|
|
|
|
To enable all optional features (BIOS, inspection, RAID, and vendor passthru),
|
|
use the following configuration:
|
|
|
|
.. code-block:: ini
|
|
|
|
[DEFAULT]
|
|
enabled_hardware_types=idrac
|
|
enabled_bios_interfaces=redfish
|
|
enabled_firmware_interfaces=redfish
|
|
enabled_inspect_interfaces=idrac-redfish
|
|
enabled_management_interfaces=idrac-redfish
|
|
enabled_power_interfaces=idrac-redfish
|
|
enabled_raid_interfaces=idrac-redfish
|
|
enabled_vendor_interfaces=idrac-redfish
|
|
|
|
Below is the list of supported interface implementations in priority
|
|
order:
|
|
|
|
================ ===================================================
|
|
Interface Supported Implementations
|
|
================ ===================================================
|
|
``bios`` ``idrac-redfish``, ``no-bios``
|
|
``boot`` ``ipxe``, ``pxe``, ``http-ipxe``, ``http``,
|
|
``redfish-https``, ``idrac-redfish-virtual-media``
|
|
``console`` ``no-console``
|
|
``deploy`` ``direct``, ``ansible``, ``ramdisk``
|
|
``firmware`` ``redfish``, ``no-firmware``
|
|
``inspect`` ``idrac-redfish``,
|
|
``inspector``, ``no-inspect``
|
|
``management`` ``idrac-redfish``
|
|
``network`` ``flat``, ``neutron``, ``noop``
|
|
``power`` ``redfish``, ``idrac-redfish``
|
|
``raid`` ``idrac-redfish``, ``no-raid``
|
|
``rescue`` ``no-rescue``, ``agent``
|
|
``storage`` ``noop``, ``cinder``, ``external``
|
|
``vendor`` ``redfish``, ``idrac-redfish``,
|
|
``no-vendor``
|
|
================ ===================================================
|
|
|
|
Protocol-specific Properties
|
|
----------------------------
|
|
|
|
The Redfish protocols require different properties to be specified
|
|
in the Ironic node's ``driver_info`` field to communicate with the bare
|
|
metal system's iDRAC.
|
|
|
|
The Redfish protocol requires the following properties:
|
|
|
|
* ``redfish_username``: The Redfish user name to use when
|
|
communicating with the iDRAC. Usually ``root``.
|
|
* ``redfish_password``: The password for the Redfish user to use
|
|
when communicating with the iDRAC.
|
|
* ``redfish_address``: The URL address of the iDRAC. It must include the
|
|
authority portion of the URL, and can optionally include the scheme. If
|
|
the scheme is missing, https is assumed.
|
|
* ``redfish_system_id``: The Redfish ID of the server to be
|
|
managed. This should always be: ``/redfish/v1/Systems/System.Embedded.1``.
|
|
|
|
For other Redfish protocol parameters see :doc:`/admin/drivers/redfish`.
|
|
|
|
Enrolling
|
|
---------
|
|
|
|
The following command enrolls a bare metal node with the ``idrac``
|
|
hardware type using Redfish for all interfaces:
|
|
|
|
.. code-block:: bash
|
|
|
|
baremetal node create --driver idrac \
|
|
--driver-info redfish_username=user \
|
|
--driver-info redfish_password=pa$$w0rd \
|
|
--driver-info redfish_address=drac.host \
|
|
--driver-info redfish_system_id=/redfish/v1/Systems/System.Embedded.1 \
|
|
--bios-interface redfish \
|
|
--inspect-interface idrac-redfish \
|
|
--management-interface idrac-redfish \
|
|
--power-interface redfish \
|
|
--raid-interface idrac-redfish \
|
|
--vendor-interface redfish
|
|
|
|
BIOS Interface
|
|
==============
|
|
|
|
The BIOS interface implementations supported by the ``idrac`` hardware type
|
|
allows BIOS to be configured with the standard clean/deploy step approach.
|
|
|
|
Example
|
|
-------
|
|
A clean step to enable ``Virtualization`` and ``SRIOV`` in BIOS of an iDRAC
|
|
BMC would be as follows::
|
|
|
|
{
|
|
"target":"clean",
|
|
"clean_steps": [
|
|
{
|
|
"interface": "bios",
|
|
"step": "apply_configuration",
|
|
"args": {
|
|
"settings": [
|
|
{
|
|
"name": "ProcVirtualization",
|
|
"value": "Enabled"
|
|
},
|
|
{
|
|
"name": "SriovGlobalEnable",
|
|
"value": "Enabled"
|
|
}
|
|
]
|
|
}
|
|
}
|
|
]
|
|
}
|
|
|
|
See the `Known Issues`_ for a known issue with ``factory_reset`` clean step.
|
|
For additional details of BIOS configuration, see :doc:`/admin/bios`.
|
|
|
|
Inspect Interface
|
|
=================
|
|
|
|
The Dell iDRAC out-of-band inspection process catalogs all the same
|
|
attributes of the server as the IPMI driver. Unlike IPMI, it does this
|
|
without requiring the system to be rebooted, or even to be powered on.
|
|
Inspection is performed using the Redfish protocol directly
|
|
without affecting the operation of the system being inspected.
|
|
|
|
The inspection discovers the following properties:
|
|
|
|
* ``cpu_arch``: cpu architecture
|
|
* ``local_gb``: disk size in gigabytes
|
|
* ``memory_mb``: memory size in megabytes
|
|
|
|
Extra capabilities:
|
|
|
|
* ``boot_mode``: UEFI or BIOS boot mode.
|
|
* ``pci_gpu_devices``: number of GPU devices connected to the bare metal.
|
|
|
|
It also creates baremetal ports for each NIC port detected in the system.
|
|
The ``idrac-redfish`` inspect interface does not currently set ``pxe_enabled``
|
|
on the ports. The user should ensure that ``pxe_enabled`` is set correctly on
|
|
the ports following inspection with the ``idrac-redfish`` inspect interface.
|
|
|
|
Management Interface
|
|
====================
|
|
|
|
The management interface for ``idrac-redfish`` supports:
|
|
|
|
* updating firmware on nodes using a manual cleaning step. See
|
|
:doc:`/admin/drivers/redfish` for more information on firmware update
|
|
support.
|
|
* updating system and getting its inventory using configuration molds. For more
|
|
information see `Import and export configuration`_.
|
|
|
|
|
|
Import and export configuration
|
|
-------------------------------
|
|
|
|
.. warning::
|
|
This feature has been deprecated and is anticipated to be removed once
|
|
Ironic has a generalized interface for doing step template articulation
|
|
for aspects beyond just "deployment" of baremetal nodes.
|
|
|
|
The clean and deploy steps provided in this section allow to configure the
|
|
system and collect the system inventory using configuration mold files.
|
|
|
|
The introduction of this feature in the Wallaby release is experimental.
|
|
|
|
These steps are:
|
|
|
|
* ``export_configuration`` with the ``export_configuration_location`` input
|
|
parameter to export the configuration from the existing system.
|
|
* ``import_configuration`` with the ``import_configuration_location`` input
|
|
parameter to import the existing configuration mold into the system.
|
|
* ``import_export_configuration`` with the ``export_configuration_location``
|
|
and ``import_configuration_location`` input parameters. This step combines
|
|
the previous two steps into one step that first imports existing
|
|
configuration mold into system, then exports the resulting configuration.
|
|
|
|
The input parameters provided include the URL where the configuration mold is
|
|
to be stored after the export, or the reference location for an import. For
|
|
more information on setting up storage and available options see
|
|
`Storage setup`_.
|
|
|
|
Configuration molds are JSON files that contain three top-level sections:
|
|
``bios``, ``raid`` and ``oem``. The following is an example of a configuration
|
|
mold:
|
|
|
|
.. code-block::
|
|
|
|
{
|
|
"bios": {
|
|
"reset": false,
|
|
"settings": [
|
|
{
|
|
"name": "ProcVirtualization",
|
|
"value": "Enabled"
|
|
},
|
|
{
|
|
"name": "MemTest",
|
|
"value": "Disabled"
|
|
}
|
|
]
|
|
}
|
|
"raid": {
|
|
"create_nonroot_volumes": true,
|
|
"create_root_volume": true,
|
|
"delete_existing": false,
|
|
"target_raid_config": {
|
|
"logical_disks": [
|
|
{
|
|
"size_gb": 50,
|
|
"raid_level": "1+0",
|
|
"controller": "RAID.Integrated.1-1",
|
|
"volume_name": "root_volume",
|
|
"is_root_volume": true,
|
|
"physical_disks": [
|
|
"Disk.Bay.0:Encl.Int.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.1:Encl.Int.0-1:RAID.Integrated.1-1"
|
|
]
|
|
},
|
|
{
|
|
"size_gb": 100,
|
|
"raid_level": "5",
|
|
"controller": "RAID.Integrated.1-1",
|
|
"volume_name": "data_volume",
|
|
"physical_disks": [
|
|
"Disk.Bay.2:Encl.Int.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.3:Encl.Int.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.4:Encl.Int.0-1:RAID.Integrated.1-1"
|
|
]
|
|
}
|
|
]
|
|
}
|
|
}
|
|
"oem": {
|
|
"interface": "idrac-redfish",
|
|
"data": {
|
|
"SystemConfiguration": {
|
|
"Model": "PowerEdge R640",
|
|
"ServiceTag": "8CY9Z99",
|
|
"TimeStamp": "Fri Jun 26 08:43:15 2020",
|
|
"Components": [
|
|
{
|
|
[...]
|
|
"FQDD": "NIC.Slot.1-1-1",
|
|
"Attributes": [
|
|
{
|
|
"Name": "BlnkLeds",
|
|
"Value": "15",
|
|
"Set On Import": "True",
|
|
"Comment": "Read and Write"
|
|
},
|
|
{
|
|
"Name": "VirtMacAddr",
|
|
"Value": "00:00:00:00:00:00",
|
|
"Set On Import": "False",
|
|
"Comment": "Read and Write"
|
|
},
|
|
{
|
|
"Name": "VirtualizationMode",
|
|
"Value": "NONE",
|
|
"Set On Import": "True",
|
|
"Comment": "Read and Write"
|
|
},
|
|
[...]
|
|
]
|
|
}
|
|
]
|
|
}
|
|
}
|
|
}
|
|
|
|
Currently, the OEM section is the only section that is supported. The OEM
|
|
section uses the iDRAC Server Configuration Profile (SCP) and can be edited as
|
|
necessary if it complies with the SCP. For more information about SCP and its
|
|
capabilities, see SCP_Reference_Guide_.
|
|
|
|
.. NOTE::
|
|
iDRAC BMC connection settings are not exported to avoid overwriting these in
|
|
another system when using unmodified exported configuration mold in import
|
|
step. If need to replicate iDRAC BMC connection settings, then add these
|
|
settings manually to configuration mold for import step.
|
|
|
|
To replicate the system configuration to that of a similar system, perform the
|
|
following steps:
|
|
|
|
#. Configure a golden, or one to many, system.
|
|
#. Use the ``export_configuration`` step to export the configuration to the
|
|
wanted location.
|
|
#. Adjust the exported configuration mold for other systems to replicate. For
|
|
example, remove sections that do not need to be replicated such as iDRAC
|
|
connection settings. The configuration mold can be accessed directly from
|
|
the storage location.
|
|
#. Import the selected configuration mold into the other systems using the
|
|
``import_configuration`` step.
|
|
|
|
It is not mandatory to use ``export_configuration`` step to create a
|
|
configuration mold. Upload the file to a designated storage location without
|
|
using Ironic if it has been created manually or by other means.
|
|
|
|
Storage setup
|
|
^^^^^^^^^^^^^
|
|
|
|
To start using these steps, configure the storage location. The settings can be
|
|
found in the ``[molds]`` section. Configure the storage type from the
|
|
:oslo.config:option:`molds.storage` setting. Currently, ``swift``, which is enabled by default,
|
|
and ``http`` are supported.
|
|
|
|
In the setup input parameters, the complete HTTP URL is used. This requires
|
|
that the containers (for ``swift``) and the directories (for ``http``) are
|
|
created beforehand, and that read/write access is configured accordingly.
|
|
|
|
.. NOTE::
|
|
Use of TLS is strongly advised.
|
|
|
|
This setup configuration allows a user to access these locations outside of
|
|
Ironic to list, create, update, and delete the configuration molds.
|
|
|
|
For more information see `Swift configuration`_ and `HTTP configuration`_.
|
|
|
|
Swift configuration
|
|
~~~~~~~~~~~~~~~~~~~
|
|
|
|
To use Swift with configuration molds,
|
|
|
|
#. Create the containers to be used for configuration mold storage.
|
|
#. For Ironic Swift user that is configured in the ``[swift]`` section add
|
|
read/write access to these containers.
|
|
|
|
HTTP configuration
|
|
~~~~~~~~~~~~~~~~~~
|
|
|
|
To use HTTP server with configuration molds,
|
|
|
|
#. Enable HTTP PUT support.
|
|
#. Create the directory to be used for the configuration mold storage.
|
|
#. Configure read/write access for HTTP Basic access authentication and provide
|
|
user credentials in :oslo.config:option:`molds.user` and :oslo.config:option:`molds.password` fields.
|
|
|
|
The HTTP web server does not support multitenancy and is intended to be used in
|
|
a stand-alone Ironic, or single-tenant OpenStack environment.
|
|
|
|
RAID Interface
|
|
==============
|
|
|
|
See :doc:`/admin/raid` for more information on Ironic RAID support.
|
|
|
|
RAID interface of ``redfish`` hardware type can be used on iDRAC systems.
|
|
Compared to ``redfish`` RAID interface, using ``idrac-redfish`` adds:
|
|
|
|
* Waiting for real-time operations to be available on RAID controllers. When
|
|
using ``redfish`` this is not guaranteed and reboots might be intermittently
|
|
required to complete,
|
|
* Converting non-RAID disks to RAID mode if there are any,
|
|
* Clearing foreign configuration, if any, after deleting virtual disks.
|
|
|
|
The following properties are supported by the Redfish RAID
|
|
interface implementation:
|
|
|
|
.. NOTE::
|
|
When using ``idrac-redfish`` for RAID interface iDRAC firmware greater than
|
|
4.40.00.00 is required.
|
|
|
|
Mandatory properties
|
|
--------------------
|
|
|
|
* ``size_gb``: Size in gigabytes (integer) for the logical disk. Use ``MAX`` as
|
|
``size_gb`` if this logical disk is supposed to use the rest of the space available.
|
|
* ``raid_level``: RAID level for the logical disk. Valid values are
|
|
``0``, ``1``, ``5``, ``6``, ``1+0``, ``5+0`` and ``6+0``.
|
|
|
|
.. NOTE::
|
|
``JBOD`` and ``2`` are not supported, and will fail with reason: 'Cannot
|
|
calculate spans for RAID level.'
|
|
|
|
Optional properties
|
|
-------------------
|
|
|
|
* ``is_root_volume``: Optional. Specifies whether this disk is a root volume.
|
|
By default, this is ``False``.
|
|
* ``volume_name``: Optional. Name of the volume to be created. If this is not
|
|
specified, it will be auto-generated.
|
|
|
|
Backing physical disk hints
|
|
---------------------------
|
|
|
|
See :doc:`/admin/raid` for more information on backing disk hints.
|
|
|
|
These are machine-independent information. The hints are specified for each
|
|
logical disk to help Ironic find the desired disks for RAID configuration.
|
|
|
|
* ``disk_type``
|
|
* ``interface_type``
|
|
* ``share_physical_disks``
|
|
* ``number_of_physical_disks``
|
|
|
|
Backing physical disks
|
|
----------------------
|
|
|
|
These are Dell RAID controller-specific values and must match the
|
|
names provided by the iDRAC.
|
|
|
|
* ``controller``: Mandatory. The name of the controller to use.
|
|
* ``physical_disks``: Optional. The names of the physical disks to use.
|
|
|
|
.. NOTE::
|
|
``physical_disks`` is a mandatory parameter if the property ``size_gb`` is set to ``MAX``.
|
|
|
|
Examples
|
|
--------
|
|
|
|
Creation of RAID ``1+0`` logical disk with six disks on one controller:
|
|
|
|
.. code-block:: json
|
|
|
|
{ "logical_disks":
|
|
[ { "controller": "RAID.Integrated.1-1",
|
|
"is_root_volume": "True",
|
|
"physical_disks": [
|
|
"Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.2:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.3:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.4:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.5:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
|
|
"raid_level": "1+0",
|
|
"size_gb": "MAX"}]}
|
|
|
|
|
|
Manual RAID Invocation
|
|
----------------------
|
|
|
|
The following command can be used to delete any existing RAID configuration.
|
|
It deletes all virtual disks/RAID volumes, unassigns all global and dedicated
|
|
hot spare physical disks, and clears foreign configuration:
|
|
|
|
.. code-block:: bash
|
|
|
|
baremetal node clean --clean-steps \
|
|
'[{"interface": "raid", "step": "delete_configuration"}]' ${node_uuid}
|
|
|
|
|
|
The following command shows an example of how to set the target RAID
|
|
configuration:
|
|
|
|
.. code-block:: bash
|
|
|
|
baremetal node set --target-raid-config '{ "logical_disks":
|
|
[ { "controller": "RAID.Integrated.1-1",
|
|
"is_root_volume": true,
|
|
"physical_disks": [
|
|
"Disk.Bay.0:Enclosure.Internal.0-1:RAID.Integrated.1-1",
|
|
"Disk.Bay.1:Enclosure.Internal.0-1:RAID.Integrated.1-1"],
|
|
"raid_level": "0",
|
|
"size_gb": "MAX"}]}' ${node_uuid}
|
|
|
|
|
|
The following command can be used to create a RAID configuration:
|
|
|
|
.. code-block:: bash
|
|
|
|
baremetal node clean --clean-steps \
|
|
'[{"interface": "raid", "step": "create_configuration"}]' <node>
|
|
|
|
|
|
When the physical disk names or controller names are not known, the
|
|
following Python code example shows how the ``python-dracclient`` can
|
|
be used to fetch the information directly from the Dell bare metal:
|
|
|
|
.. code-block:: python
|
|
|
|
import dracclient.client
|
|
|
|
|
|
client = dracclient.client.DRACClient(
|
|
host="192.168.1.1",
|
|
username="root",
|
|
password="calvin")
|
|
controllers = client.list_raid_controllers()
|
|
print(controllers)
|
|
|
|
physical_disks = client.list_physical_disks()
|
|
print(physical_disks)
|
|
|
|
Or using ``sushy`` with Redfish:
|
|
|
|
.. code-block:: python
|
|
|
|
import sushy
|
|
|
|
|
|
client = sushy.Sushy('https://192.168.1.1', username='root', password='calvin', verify=False)
|
|
for s in client.get_system_collection().get_members():
|
|
print("System: %(id)s" % {'id': s.identity})
|
|
for c in system1.storage.get_members():
|
|
print("\tController: %(id)s" % {'id': c.identity})
|
|
for d in c.drives:
|
|
print("\t\tDrive: %(id)s" % {'id': d.identity})
|
|
|
|
Vendor Interface
|
|
================
|
|
|
|
idrac-redfish
|
|
-------------
|
|
|
|
Through the ``idrac-redfish`` vendor passthru interface these methods are
|
|
available:
|
|
|
|
================ ============ ==============================================
|
|
Method Name HTTP Method Description
|
|
================ ============ ==============================================
|
|
``eject_media`` ``POST`` Eject a virtual media device. If no device is
|
|
provided then all attached devices will be
|
|
ejected. Optional argument: ``boot_device`` -
|
|
the boot device to eject, either, ``cd``,
|
|
``dvd``, ``usb`` or ``floppy``.
|
|
================ ============ ==============================================
|
|
|
|
Known Issues
|
|
============
|
|
|
|
Nodes go into maintenance mode
|
|
------------------------------
|
|
|
|
After some period of time, nodes managed by the ``idrac`` hardware type may go
|
|
into maintenance mode in Ironic. This issue can be worked around by changing
|
|
the Ironic power state poll interval to 70 seconds. See
|
|
:oslo.config:option:`conductor.sync_power_state_interval` in ``/etc/ironic/ironic.conf``.
|
|
|
|
PXE reset with "factory_reset" BIOS clean step
|
|
----------------------------------------------
|
|
|
|
When using the ``UEFI boot mode`` with non-default PXE interface, the factory
|
|
reset can cause the PXE interface to be reset to default, which doesn't allow
|
|
the server to PXE boot for any further operations. This can cause a
|
|
``clean_failed`` state on the node or ``deploy_failed`` if you attempt to
|
|
deploy a node after this step. For now, the only solution is for the operator
|
|
to manually restore the PXE settings of the server for it to PXE boot again,
|
|
properly.
|
|
The problem is caused by the fact that with the ``UEFI boot mode``, the
|
|
``idrac`` uses BIOS settings to manage PXE configuration. This is not the case
|
|
with the ``BIOS boot mode`` where the PXE configuration is handled as a
|
|
configuration job on the integrated NIC itself, independently of the BIOS
|
|
settings.
|
|
|
|
.. _Ironic_RAID: https://docs.openstack.org/ironic/latest/admin/raid.html
|
|
.. _iDRAC: https://www.dell.com/idracmanuals
|
|
|
|
Timeout when powering off
|
|
-------------------------
|
|
|
|
Some servers might be slow when soft powering off and time out. The default retry count
|
|
is 6, resulting in 30 seconds timeout (the default retry interval set by
|
|
``post_deploy_get_power_state_retry_interval`` is 5 seconds).
|
|
To resolve this issue, increase the timeout to 90 seconds by setting the retry count to
|
|
18 as follows:
|
|
|
|
.. code-block:: ini
|
|
|
|
[agent]
|
|
post_deploy_get_power_state_retries = 18
|
|
|
|
Unable to mount remote share with iDRAC firmware before 4.40.40.00
|
|
------------------------------------------------------------------
|
|
|
|
When using iDRAC firmware 4.40.00.00 and consecutive versions before 4.40.40.00
|
|
with virtual media boot and new Virtual Console plug-in type eHTML5, there is
|
|
an error: "Unable to mount remote share". This is a known issue that is fixed
|
|
in 4.40.40.00 iDRAC firmware release. If cannot upgrade, then adjust settings
|
|
in iDRAC to use plug-in type HTML5. In iDRAC web UI go to Configuration ->
|
|
Virtual Console and select Plug-in Type to HTML5.
|
|
|
|
During upgrade to 4.40.00.00 or newer iDRAC firmware eHTML5 is automatically
|
|
selected if default plug-in type has been used and never changed. Systems that
|
|
have plug-in type changed will keep selected plug-in type after iDRAC firmware
|
|
upgrade.
|
|
|
|
Firmware update from Swift fails before 6.00.00.00
|
|
--------------------------------------------------
|
|
|
|
With iDRAC firmware prior to 6.00.00.00 and when using Swift to stage firmware
|
|
update files in Management interface ``firmware_update`` clean step of
|
|
``redfish`` or ``idrac`` hardware type, the cleaning fails with error
|
|
"An internal error occurred. Unable to complete the specified operation." in
|
|
iDRAC job. This is fixed in iDRAC firmware 6.00.00.00. If cannot upgrade, then
|
|
use HTTP service to stage firmware files for iDRAC.
|
|
|
|
.. _SCP_Reference_Guide: http://downloads.dell.com/manuals/common/dellemc-server-config-profile-refguide.pdf
|